Abstract
OBJECTIVE:
To determine whether the use of glucagon-like peptide-1 (GLP-1) analogues, compared with the use of dipeptidylpeptidase-4 (DPP-4) inhibitors, is associated with an increased risk of incident breast cancer in patients with type 2 diabetes.
DESIGN:
Population based cohort study.
SETTING:
Clinical Practice Research Datalink, UK.
PARTICIPANTS:
44 984 women aged at least 40 years, who were newly treated with glucose lowering drugs between 1 January 2007 and 31 March 2015, with follow-up until 31 March 2016.
MAIN OUTCOMES AND MEASURES:
Time varying use of GLP-1 analogues compared with use of DPP-4 inhibitors, with exposures lagged by one year for latency purposes. Time dependent Cox proportional hazards models were used to estimate adjusted hazard ratios with 95% confidence intervals of incident breast cancer associated with use of GLP-1 analogues overall, by cumulative duration of use, and time since initiation.
RESULTS:
The cohort was followed for a mean of 3.5 years (standard deviation 2.2), with 549 incident events of breast cancer recorded (crude incidence 3.5 (95% confidence interval 3.3 to 3.8) per 1000 person years). Overall, compared with use of DPP-4 inhibitors, use of GLP-1 analogues was not associated with an increased risk of breast cancer (incidence 4.4 v 3.4 per 1000 person years; hazard ratio 1.40 (95% confidence interval 0.91 to 2.16)). Hazard ratios gradually increased with longer durations of use, with a peak between two to three years of GLP-1 use (2.66 (95% confidence interval 1.32 to 5.38)), and returned closer to the null after more than three years of use (0.98 (0.24 to 4.03)). A similar pattern was observed with time since initiation of GLP-1 analogues.
CONCLUSIONS:
In this population based cohort study, use of GLP-1 analogues was not associated with an overall increased risk of breast cancer. Although it is not possible to rule out a tumour promoter effect, the observed duration-response associations are likely the result of a transient increase in detection of breast cancers in GLP-1 analogue users.
To determine whether the use of glucagon-like peptide-1 (GLP-1) analogues, compared with the use of dipeptidylpeptidase-4 (DPP-4) inhibitors, is associated with an increased risk of incident breast cancer in patients with type 2 diabetes.
DESIGN:
Population based cohort study.
SETTING:
Clinical Practice Research Datalink, UK.
PARTICIPANTS:
44 984 women aged at least 40 years, who were newly treated with glucose lowering drugs between 1 January 2007 and 31 March 2015, with follow-up until 31 March 2016.
MAIN OUTCOMES AND MEASURES:
Time varying use of GLP-1 analogues compared with use of DPP-4 inhibitors, with exposures lagged by one year for latency purposes. Time dependent Cox proportional hazards models were used to estimate adjusted hazard ratios with 95% confidence intervals of incident breast cancer associated with use of GLP-1 analogues overall, by cumulative duration of use, and time since initiation.
RESULTS:
The cohort was followed for a mean of 3.5 years (standard deviation 2.2), with 549 incident events of breast cancer recorded (crude incidence 3.5 (95% confidence interval 3.3 to 3.8) per 1000 person years). Overall, compared with use of DPP-4 inhibitors, use of GLP-1 analogues was not associated with an increased risk of breast cancer (incidence 4.4 v 3.4 per 1000 person years; hazard ratio 1.40 (95% confidence interval 0.91 to 2.16)). Hazard ratios gradually increased with longer durations of use, with a peak between two to three years of GLP-1 use (2.66 (95% confidence interval 1.32 to 5.38)), and returned closer to the null after more than three years of use (0.98 (0.24 to 4.03)). A similar pattern was observed with time since initiation of GLP-1 analogues.
CONCLUSIONS:
In this population based cohort study, use of GLP-1 analogues was not associated with an overall increased risk of breast cancer. Although it is not possible to rule out a tumour promoter effect, the observed duration-response associations are likely the result of a transient increase in detection of breast cancers in GLP-1 analogue users.
Original language | English |
---|---|
Article number | i5340 |
Number of pages | 8 |
Journal | British Medical Journal |
Volume | 355 |
DOIs | |
Publication status | Published - 20 Oct 2016 |
Externally published | Yes |