Abstract
Despite growing concerns about overheating, a lack of evidence exists on the scale of the problem, particularly in contemporary UK housing. This paper presents the results of a meta-analysis of indoor temperatures in selected low-energy housing. Temperature data recorded at five-minute intervals in 60 dwellings across 19 demonstration projects (2012–14) were collated and analysed to investigate the prevalence of overheating. Findings evidence high summertime temperatures, with 278°C during August. Based on the Chartered Institution of Building Services Engineers (CIBSE) threshold of 5 25°C, 575 30 3 1 K. The results suggest a fundamental relationship between ventilation and indoor temperatures. The higher minimum and average summertime temperatures observed in mechanical ventilation with heat recovery (MVHR) homes (p < 0.05) and lower temperature range (p < 0.001) suggest the need for greater attention to adequate summertime ventilation provision in airtight homes. The results demonstrate a high prevalence of overheating in exemplary housing, indicating the need for greater efforts to ensure the effective implementation of strategies to minimize overheating and improve ventilation in low-energy homes.
| Original language | English |
|---|---|
| Pages (from-to) | 19-39 |
| Number of pages | 21 |
| Journal | Building Research and Information |
| Volume | 45 |
| Issue number | 1-2 |
| Early online date | 20 Sept 2016 |
| DOIs | |
| Publication status | Published - 17 Feb 2017 |
| Externally published | Yes |
Keywords
- building performance
- heat stress
- housing
- low-energy buildings
- overheating
- thermal performance
- ventilation
- vulnerability
Fingerprint
Dive into the research topics of 'Meta-analysis of indoor temperatures in new-build housing'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver