TY - JOUR
T1 - Micro-CT based finite element models of cancellous bone predict accurately displacement once the boundary condition is well replicated
T2 - A validation study
AU - Chen, Yuan
AU - Dall׳Ara, Enrico
AU - Sales, Erika
AU - Manda, Krishnagoud
AU - Wallace, Robert
AU - Pankaj, Pankaj
AU - Viceconti, Marco
PY - 2017/1/1
Y1 - 2017/1/1
N2 - Non-destructive 3D micro-computed tomography (microCT) based finite element (microFE) models are used to estimate bone mechanical properties at tissue level. However, their validation remains challenging. Recent improvements in the quantification of displacements in bone tissue biopsies subjected to staged compression, using refined Digital Volume Correlation (DVC) techniques, now provide a full field displacement information accurate enough to be used for microFE validation. In this study, three specimens (two humans and one bovine) were tested with two different experimental set-ups, and the resulting data processed with the same DVC algorithm. The resulting displacement vector field was compared to that predicted by microFE models solved with three different boundary conditions (BC): nominal force resultant, nominal displacement resultant, distributed displacement. The first two conditions were obtained directly from the measurements provided by the experimental jigs, whereas in the third case the displacement field measured by the DVC in the top and bottom layer of the specimen was applied. Results show excellent relationship between the numerical predictions (x) and the experiments (y) when using BC derived from the DVC measurements (UX: y=1.07x−0.002, RMSE: 0.001 mm; UY: y=1.03x−0.001, RMSE: 0.001 mm; UZ: y=x+0.0002, RMSE: 0.001 mm for bovine specimen), whereas only poor correlation was found using BCs according to experiment set-ups. In conclusion, microFE models were found to predict accurately the vectorial displacement field using interpolated displacement boundary condition from DVC measurement.
AB - Non-destructive 3D micro-computed tomography (microCT) based finite element (microFE) models are used to estimate bone mechanical properties at tissue level. However, their validation remains challenging. Recent improvements in the quantification of displacements in bone tissue biopsies subjected to staged compression, using refined Digital Volume Correlation (DVC) techniques, now provide a full field displacement information accurate enough to be used for microFE validation. In this study, three specimens (two humans and one bovine) were tested with two different experimental set-ups, and the resulting data processed with the same DVC algorithm. The resulting displacement vector field was compared to that predicted by microFE models solved with three different boundary conditions (BC): nominal force resultant, nominal displacement resultant, distributed displacement. The first two conditions were obtained directly from the measurements provided by the experimental jigs, whereas in the third case the displacement field measured by the DVC in the top and bottom layer of the specimen was applied. Results show excellent relationship between the numerical predictions (x) and the experiments (y) when using BC derived from the DVC measurements (UX: y=1.07x−0.002, RMSE: 0.001 mm; UY: y=1.03x−0.001, RMSE: 0.001 mm; UZ: y=x+0.0002, RMSE: 0.001 mm for bovine specimen), whereas only poor correlation was found using BCs according to experiment set-ups. In conclusion, microFE models were found to predict accurately the vectorial displacement field using interpolated displacement boundary condition from DVC measurement.
KW - Cancellous bone
KW - DVC
KW - MicroCT
KW - microFE
KW - Validation
UR - http://www.scopus.com/inward/record.url?scp=84991711087&partnerID=8YFLogxK
U2 - 10.1016/j.jmbbm.2016.09.014
DO - 10.1016/j.jmbbm.2016.09.014
M3 - Article
C2 - 27741494
AN - SCOPUS:84991711087
SN - 1751-6161
VL - 65
SP - 644
EP - 651
JO - Journal of the Mechanical Behavior of Biomedical Materials
JF - Journal of the Mechanical Behavior of Biomedical Materials
ER -