Abstract
A two-thermocouple sensor characterization method for use in variable flow applications is proposed. Previous offline methods for constant velocity flow are extended using sliding data windows and polynomials to accommodate variable velocity. Analysis of Monte-Carlo simulation studies confirms that the unbiased and consistent parameter estimator outperforms alternatives in the literature and has the added advantage of not requiring a priori knowledge of the time constant ratio of thermocouples. Experimental results from a test rig are also presented.
Original language | English |
---|---|
Pages (from-to) | 349-370 |
Number of pages | 22 |
Journal | Transactions of the Institute of Measurement and Control |
Volume | 30 |
Issue number | 5 |
DOIs | |
Publication status | Published - Dec 2008 |