Vaginal Hysterectomy using the ERBE BiClamp® Bipolar Vessel Sealing System: A Case Series

  • Gillian V Blayney
  • , James P Beirne
  • , Lynsey Hinds
  • , Declan Quinn
  • , Gary J Dorman

Research output: Contribution to journal › Article › peer-review

209 Downloads (Pure)

Abstract

The ERBE BiClamp® BVSS appears to be a safe and effective method of vaginal hysterectomy in this small single surgeon, single institution study; demonstrating efficient operative times, minimal blood loss and intraoperative morbidity with acceptable surgical outcomes. Its use contributes to the advancement of minimally invasive gynaecology and should be encouraged.

Original languageEnglish
Pages (from-to)167-171
Number of pages5
JournalThe Ulster Medical Journal
Volume86
Issue number3
Publication statusPublished - 01 Sept 2017

Keywords

  • Adult
  • Aged
  • Aged, 80 and over
  • Analgesics/therapeutic use
  • Blood Loss, Surgical
  • Female
  • Humans
  • Hysterectomy, Vaginal/adverse effects
  • Length of Stay
  • Middle Aged
  • Operative Time
  • Pain, Postoperative/drug therapy
  • Reoperation
  • Retrospective Studies
  • Young Adult

Fingerprint

Dive into the research topics of 'Vaginal Hysterectomy using the ERBE BiClamp® Bipolar Vessel Sealing System: A Case Series'. Together they form a unique fingerprint.

Cite this