Abstract
Purpose
To assess the 1-month and 12-month postoperative visual performance and subjective outcomes following combined implantation of an extended depth of focus (EDOF) intraocular lens (IOL) and a trifocal IOL.
Methods
The study enrolled consecutive patients undergoing refractive lens extraction or cataract surgery with combined implantation of an EDOF IOL (dominant eye) and trifocal IOL. Uncorrected (UDVA) and best-corrected (CDVA) distance visual acuities, uncorrected intermediate (UIVA) and near (UNVA) visual acuities, and subjective questionnaires were evaluated 1 month and 12 months postoperatively.
Results
The study enrolled 58 consecutive patients. Binocular UDVA, UIVA and UNVA were − 0.08 ± 0.07 logMAR, 0.15 ± 0.14 logMAR and 0.17 ± 0.11 logMAR at 1 month, compared to − 0.09 ± 0.06 logMAR (P = .323), 0.11 ± 0.10 logMAR (P = .030) and 0.13 ± 0.10 logMAR (P = 0.008) at 12 months. Satisfaction was high with 93.1% of patients fulfilled or more than fulfilled postoperatively, and 84.5% and 86.3% reported spectacle independence for near at the respective postoperative assessments. The mean daytime and nighttime quality of vision (QoV) scores were 9.12 ± 0.94 and 7.88 ± 1.74 at 1 month, compared to 9.24 ± 0.78 (P = .183) and 8.26 ± 1.38 (P = .043) at 12 months.
Conclusions
This IOL combination provides good unaided visual acuity at 1 and 12 months postoperatively, with high functional vision and postoperative satisfaction reported at 1 and 12 months. However, a significant improvement in overall nighttime QoV at the 12 months assessment was found.
To assess the 1-month and 12-month postoperative visual performance and subjective outcomes following combined implantation of an extended depth of focus (EDOF) intraocular lens (IOL) and a trifocal IOL.
Methods
The study enrolled consecutive patients undergoing refractive lens extraction or cataract surgery with combined implantation of an EDOF IOL (dominant eye) and trifocal IOL. Uncorrected (UDVA) and best-corrected (CDVA) distance visual acuities, uncorrected intermediate (UIVA) and near (UNVA) visual acuities, and subjective questionnaires were evaluated 1 month and 12 months postoperatively.
Results
The study enrolled 58 consecutive patients. Binocular UDVA, UIVA and UNVA were − 0.08 ± 0.07 logMAR, 0.15 ± 0.14 logMAR and 0.17 ± 0.11 logMAR at 1 month, compared to − 0.09 ± 0.06 logMAR (P = .323), 0.11 ± 0.10 logMAR (P = .030) and 0.13 ± 0.10 logMAR (P = 0.008) at 12 months. Satisfaction was high with 93.1% of patients fulfilled or more than fulfilled postoperatively, and 84.5% and 86.3% reported spectacle independence for near at the respective postoperative assessments. The mean daytime and nighttime quality of vision (QoV) scores were 9.12 ± 0.94 and 7.88 ± 1.74 at 1 month, compared to 9.24 ± 0.78 (P = .183) and 8.26 ± 1.38 (P = .043) at 12 months.
Conclusions
This IOL combination provides good unaided visual acuity at 1 and 12 months postoperatively, with high functional vision and postoperative satisfaction reported at 1 and 12 months. However, a significant improvement in overall nighttime QoV at the 12 months assessment was found.
Original language | English |
---|---|
Journal | International Ophthalmology |
Early online date | 21 Sept 2021 |
DOIs | |
Publication status | Early online date - 21 Sept 2021 |
Keywords
- Quality of vision
- Extended depth of focus IOL
- Cataract surgery
- Refractive lens exchange
- Trifocal IOL
- Visual outcomes